NuApps-2544-RM User’s Manual USM Ver 1.3
10Installing NuApps-2544-RM 13. WinPcap installation completes. Click Finish button to close the wizard.14. NuApps-2544-RM installation completes.
11You can uninstall NuApps-2544-RM by: Uninstalling NuApps-2544-RM • Click Start Æ Programs Æ NuStreams Æ NuApps-2544-RM Æ Uninstall NuApps-25
123. NuApps-2544-RM Function Overview 3.1. Starting NuApps-2544-RM Before starting NuApps-2544-RM, the DUT, your PC, and NuStreams-2000i/600i shall
13NuApps-2544-RM Demo Mode If your PC is not connected with NuStreams-2000i/600i, you can still run NuApps-2544-RM under Demo Mode. Almost all NuAp
14Please follow the steps down below to start NuApps-2544-RM and NuServer properly. Starting NuServer When starting NuApps-2544-RM, a “Connect
15Starting NuServer If an error message window pops up and says “Detecting NuServer System Fail”, please close NuApps-2544-RM and NuServer, and sta
16Port Reserving If the port mapping contained in the configuration file you’ve loaded from your PC does not match NuStreams-2000i/600i’s current
17Port Reserving If you would like to make a new configuration, please choose “Create a New Configuration” from the Select Config pop-up window. A
183.2. NuApps-2544-RM/NuServer Overview NuApps-2544-RM Main Window NuApps-2544-RM Functions Overview A Menu Bar The Menu Bar allows you to make se
19NuServer Description Module Card Information This section displays the information regarding to the model cards that are installed on NuStreams-
2Foreword Copyright Copyright © 2011 Xtramus Technologies, all rights reserved. The information contained in this document is the property of Xtram
204. NuApps-2544-RM Functions 4.1. Menu Bar NuApps-2544-RM Menu Bar includes configuration options such as File, View, Language, and Help. Please
21File Save/Save As… The Save/Save As… function on the Menu Bar allow you to save the settings you’ve made or the test results. To save the sett
224.1.3. Language Language English/Simplified Chinese NuApps-2544-RM has 2 different languages for its UI available. You can set the UI language t
234.2. Quick Launch Buttons These Quick Launch Buttons allow you to reconnect NuStreams-2000i/600i, open/save configuration files, module port con
24Port Config By clicking the Port Config button, the Port Configuration screen will be shown on the Main Display Screen located on the right side
254.3. System Info/Configuration List The System Info/Configuration List allows you to view system information, making port/test configurations, a
26Test Config (Throughput, Latency, Packet Loss, Back to Back) By clicking the Test Config from the System Info/Configuration List, the Test Config
274.5. Description The Description displays brief descriptions and figures regarding to Throughput, Latency, Packet Loss, and Back to Back tests.
284.8. Port Configuration Settings such as port transmitting rate, auto-negotiation, and protocol are available and can be configured on the Port C
29Port ¾ Port No./Card Type: These two fields display each port’s Port ID and the model name of its module card. ¾ Alias: You can input alias f
3E-mail: [email protected]: www.Xtramus.comXTRAMUS TECHNOLOGIES® Revision History Date Version Software History Sept, 2010 1.0 First
30Protocol ¾ Port No.: This field displays each port’s Port ID. ¾ Protocol: The Protocol scroll-down menu allows you to set each port’s protoc
314.9. Test Configuration 4 different test modes, including Throughput, Latency, Packet Loss, and Back to Back, can be configured on the Test Confi
324.9.1. Pairing/Assigning Test Ports Before making any test configurations on the Test Configuration screen, you have to make the proper port pair
33One to One In One to One test mode, packets will be sent from one source port to one destination port as shown in the figure above. Port Pair
34One to Many In One to Many test mode, packets will be sent from one source port to multiple destination ports as shown in the figure above. P
35Many to One In Many to One test mode, packets will be sent from one destination port to multiple source ports as shown in the figure above. P
36Rotate In Rotate test mode, packets will be sent from port to port in a loop while the last port will be connected to the first port, as shown i
37Port Pairing/Assigning for Rotate Mode 3. Click the 〉 button to add all the ports listed in Rotate Group Member field as a group of ports. The
384.9.2. Test Configuration Overview NuApps-2544-RM supports four different tests including: Diagram Description Throughput test determines the
394.9.3. Throughput Test Throughput test determines the DUT’s maximum capable throughput rate without dropping any packets. The Throughput configu
4Table of Contents Foreword ...
40Frame Size (bytes) Custom (Contd.) You can double-click the field you would like to customize and input the value manually. • Number of Differ
414.9.4. Latency Test Latency test measures the time it takes for the DUT to forward a packet. The load generated by NuStreams-2000i/600i can be c
42Frame Size (bytes) Custom (Contd.) You can double-click the field you would like to customize and input the value manually. • Number of Differ
434.9.5. Packet Loss Test Packet Loss test measures the percentage of packets that are not forwarded (therefore, lost) due to the lack of resource
44Frame Size (bytes) Custom (Contd.) You can double-click the field you would like to customize and input the value manually. • Number of Differ
454.9.6. Back to Back Test Back to Back test measures DUT’s buffer capacity by sending bursts of traffic at the maximum frame rate and measuring t
46Frame Size (bytes) Custom (Contd.) You can double-click the field you would like to customize and input the value manually. • Number of Differ
474.10. Report Test results, statistics and charts are displayed and can be checked on the Main Display Screen. There are two ways to view Report:
48Throughput Test Result Chart Latency Test Result Chart This chart uses Frame Count per Second as X-Axis, and Frame Size as Y-Axis to show DUT’s
49Viewing Test Result Chart (Continued) If you would like to view test result charts for other pairs of ports, please click the port pair you wou
51. NuApps-2544-RM Overview NuApps-2544-RM is an application that’s designed base on RFC-2544 for analyzing Ethernet switches, bridges, and routers
50 Note: Information and specifications contained in this document are subject to change without notice. All products and company names are tradem
62. Installing/Uninstalling NuApps-2544-RM Please follow the steps down below to install NuApps-2544-RM. Installing NuApps-2544-RM 1. Double-cli
7Installing NuApps-2544-RM 4. Click “I accept the terms in the license agreement”, and click “Next” to continue.5. You can input Username and Organ
8Installing NuApps-2544-RM 7. InstallShield Wizard is installing NuApps-2544-RM. 8. If your PC does not have WinPcap installed, a WinPcap Installer
9Installing NuApps-2544-RM 10. Review the license agreement before installing. Click I Agree button to continue. It is necessary to accept the agre
Komentarze do niniejszej Instrukcji